Svenska Designer →

3×3 m pergola – plans, timber list and sizes

A 3×3 m pergola with an open roof: top rafters 45×95 on beams 45×145 and 4 braced posts 95×95. All in pressure-treated C24 timber in standard lengths.

Frame drawing: 3×3 m pergola
Frame drawing · 3×3 m pergola · Download drawing (PNG)

Quick facts

Area
9.0 m²
Beams
45×145
Posts
4 × 95×95
Top rafters
45×95 c/c 900
Footings
4
Boards
12
Total timber
53 m

Member sizes

MemberSizeUtilisationGoverning
Top raftersspan 2.88 m · c/c ≤ 900 mm · open roof, nominal 0.4 kN/m² · g 0.06 kN/m, q 0.36 kN/m 45×95 c/c 900 97% deflection
Beams2 rows · span 2.88 m between posts · g 0.12 kN/m, q 0.70 kN/m 45×145 71% deflection
Postslength 2.40 m · N 1.5 kN (G+Q) · braced, Lef = L 95×95 6% buckling

Timber list

QtySizeLengthTreatment
7 45×95 4.8 m Pressure treated NTR/AB
1 45×95 1.8 m Pressure treated NTR/AB
2 45×145 3.9 m Pressure treated NTR/AB
2 95×95 4.8 m Pressure treated NTR/AB

FAQ

How big do the beams need to be?

The beams are 45×145. Always join beams over a post.

What rafters do I need for a 3×3 m pergola?

45×95 at 900 mm c/c in snow zone 2.0. In snow zone 3.0 you need at undefined c/c.

How much timber does it take?

The frame takes 12 boards in standard lengths, 53 m of timber in total. The cut list is optimised to keep offcuts small.

How many footings do I need?

4 footings. The most heavily loaded one carries 1.5 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.

Similar plans

All plans → · Markdown version

The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.