Svenska Designer →

6×5.4 m carport with metal roof – plans, timber list and sizes

A 6×5.4 m carport (32.4 m²) with a metal roof: rafters 45×145 at 600 c/c on beams 115×360 and 6 posts 95×95. Sized for snow zone 2.0 kN/m².

Frame drawing: 6×5.4 m carport with metal roof
Frame drawing · 6×5.4 m carport with metal roof · Download drawing (PNG)

Quick facts

Area
32.4 m²
Beams
115×360
Posts
6 × 95×95
Rafters
45×145 c/c 600
Footings
6
Boards
52
Total timber
215 m

Member sizes

MemberSizeUtilisationGoverning
Raftersspan 2.64 m · c/c ≤ 600 mm · snow 1.6 kN/m² · g 0.15 kN/m, q 0.96 kN/m 45×145 c/c 600 67% bending
Beams3 rows · span 5.88 m between posts · g 0.65 kN/m, q 4.22 kN/m 115×360 86% deflection
Postslength 2.67 m · N 16.4 kN (G+Q) · braced, Lef = L 95×95 78% buckling
Battensspan 0.59 m between rafters · g 0.12 kN/m, s 0.96 kN/m 28×70 c/c 600 59% deflection

Rafters by snow zone

Ground snow load sₖ (kN/m²)Size
1.0Malmö, Helsingborg 45×220 c/c 600
1.5Göteborg, Kalmar 45×120 c/c 600
2.0Stockholm 45×145 c/c 600
2.5Karlstad, Gävle 45×145 c/c 600
3.0Sundsvall, Umeå 45×145 c/c 600
3.5Luleå 45×195 c/c 900
4.5mountain areas 45×120 c/c 600
5.5high mountains 45×145 c/c 600

Timber list

QtySizeLengthTreatment
11 28×70 5.1 m C24 untreated
3 28×70 4.8 m C24 untreated
1 28×70 3.3 m C24 untreated
1 45×95 5.4 m Pressure treated NTR/AB
2 45×95 4.8 m Pressure treated NTR/AB
1 45×95 3.0 m Pressure treated NTR/AB
26 45×145 3.3 m Pressure treated NTR/AB
2 95×95 4.8 m Pressure treated NTR/AB
2 95×95 3.0 m Pressure treated NTR/AB
3 115×360 7.2 m Glulam GL30c

Good to know

FAQ

How big do the beams need to be?

The beams are 115×360. Always join beams over a post.

What rafters do I need for a 6×5.4 m carport with metal roof?

45×145 at 600 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×195 at 900 c/c.

How much timber does it take?

The frame takes 52 boards in standard lengths, 215 m of timber in total. The cut list is optimised to keep offcuts small.

How many footings do I need?

6 footings. The most heavily loaded one carries 16.4 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.

Do I need a building permit?

Over 15 m² the building no longer counts as a friggebod (permit-free outbuilding). It then usually needs an attefall notification or a building permit. Ask your municipality.

Similar plans

All plans → · Markdown version

The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.