6×5.4 m carport with metal roof – plans, timber list and sizes
A 6×5.4 m carport (32.4 m²) with a metal roof: rafters 45×145 at 600 c/c on beams 115×360 and 6 posts 95×95. Sized for snow zone 2.0 kN/m².
Quick facts
- Area
- 32.4 m²
- Beams
- 115×360
- Posts
- 6 × 95×95
- Rafters
- 45×145 c/c 600
- Footings
- 6
- Boards
- 52
- Total timber
- 215 m
Member sizes
| Member | Size | Utilisation | Governing |
|---|---|---|---|
| Raftersspan 2.64 m · c/c ≤ 600 mm · snow 1.6 kN/m² · g 0.15 kN/m, q 0.96 kN/m | 45×145 c/c 600 | 67% | bending |
| Beams3 rows · span 5.88 m between posts · g 0.65 kN/m, q 4.22 kN/m | 115×360 | 86% | deflection |
| Postslength 2.67 m · N 16.4 kN (G+Q) · braced, Lef = L | 95×95 | 78% | buckling |
| Battensspan 0.59 m between rafters · g 0.12 kN/m, s 0.96 kN/m | 28×70 c/c 600 | 59% | deflection |
Rafters by snow zone
| Ground snow load sₖ (kN/m²) | Size |
|---|---|
| 1.0Malmö, Helsingborg | 45×220 c/c 600 |
| 1.5Göteborg, Kalmar | 45×120 c/c 600 |
| 2.0Stockholm | 45×145 c/c 600 |
| 2.5Karlstad, Gävle | 45×145 c/c 600 |
| 3.0Sundsvall, Umeå | 45×145 c/c 600 |
| 3.5Luleå | 45×195 c/c 900 |
| 4.5mountain areas | 45×120 c/c 600 |
| 5.5high mountains | 45×145 c/c 600 |
Timber list
| Qty | Size | Length | Treatment |
|---|---|---|---|
| 11 | 28×70 | 5.1 m | C24 untreated |
| 3 | 28×70 | 4.8 m | C24 untreated |
| 1 | 28×70 | 3.3 m | C24 untreated |
| 1 | 45×95 | 5.4 m | Pressure treated NTR/AB |
| 2 | 45×95 | 4.8 m | Pressure treated NTR/AB |
| 1 | 45×95 | 3.0 m | Pressure treated NTR/AB |
| 26 | 45×145 | 3.3 m | Pressure treated NTR/AB |
| 2 | 95×95 | 4.8 m | Pressure treated NTR/AB |
| 2 | 95×95 | 3.0 m | Pressure treated NTR/AB |
| 3 | 115×360 | 7.2 m | Glulam GL30c |
Good to know
- Covered roofs catch the wind: anchor every post against uplift (cast-in anchors or bolted post bases). Wind uplift is not checked.
FAQ
How big do the beams need to be?
The beams are 115×360. Always join beams over a post.
What rafters do I need for a 6×5.4 m carport with metal roof?
45×145 at 600 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×195 at 900 c/c.
How much timber does it take?
The frame takes 52 boards in standard lengths, 215 m of timber in total. The cut list is optimised to keep offcuts small.
How many footings do I need?
6 footings. The most heavily loaded one carries 16.4 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.
Do I need a building permit?
Over 15 m² the building no longer counts as a friggebod (permit-free outbuilding). It then usually needs an attefall notification or a building permit. Ask your municipality.
Similar plans
The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.