Svenska Designer →

3×5 m carport with felt roof – plans, timber list and sizes

A 3×5 m carport (15.0 m²) with a felt roof: rafters 45×170 at 1200 c/c on beams 2 × 45×220 and 6 posts 95×95. Sized for snow zone 2.0 kN/m².

Frame drawing: 3×5 m carport with felt roof
Frame drawing · 3×5 m carport with felt roof · Download drawing (PNG)

Quick facts

Area
15.0 m²
Beams
2 × 45×220
Posts
6 × 95×95
Rafters
45×170 c/c 1200
Footings
6
Boards
21
Total timber
91 m

Member sizes

MemberSizeUtilisationGoverning
Raftersspan 2.44 m · c/c ≤ 1,200 mm · snow 1.6 kN/m² · g 0.39 kN/m, q 1.92 kN/m 45×170 c/c 1200 87% bending
Beams3 rows · span 2.88 m between posts · g 0.80 kN/m, q 3.90 kN/m 2 × 45×220 82% bending
Postslength 2.64 m · N 8.3 kN (G+Q) · braced, Lef = L 95×95 39% buckling

Rafters by snow zone

Ground snow load sₖ (kN/m²)Size
1.0Malmö, Helsingborg 45×145 c/c 1200
1.5Göteborg, Kalmar 45×145 c/c 1200
2.0Stockholm 45×170 c/c 1200
2.5Karlstad, Gävle 45×195 c/c 1200
3.0Sundsvall, Umeå 45×145 c/c 1200
3.5Luleå 45×145 c/c 1200
4.5mountain areas 45×220 c/c 900
5.5high mountains 45×170 c/c 1200

Timber list

QtySizeLengthTreatment
1 45×95 5.4 m Pressure treated NTR/AB
2 45×95 5.1 m Pressure treated NTR/AB
1 45×95 1.8 m Pressure treated NTR/AB
6 45×170 5.4 m Pressure treated NTR/AB
1 45×170 2.4 m Pressure treated NTR/AB
6 45×220 3.9 m Pressure treated NTR/AB
2 95×95 4.8 m Pressure treated NTR/AB
2 95×95 3.0 m Pressure treated NTR/AB

Good to know

FAQ

How big do the beams need to be?

The beams are 2 × 45×220. Always join beams over a post.

What rafters do I need for a 3×5 m carport with felt roof?

45×170 at 1200 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×145 at 1200 c/c.

How much timber does it take?

The frame takes 21 boards in standard lengths, 91 m of timber in total. The cut list is optimised to keep offcuts small.

How many footings do I need?

6 footings. The most heavily loaded one carries 8.3 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.

Similar plans

All plans → · Markdown version

The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.