3×5 m carport with metal roof – plans, timber list and sizes
A 3×5 m carport (15.0 m²) with a metal roof: rafters 45×120 at 600 c/c on beams 2 × 45×220 and 6 posts 95×95. Sized for snow zone 2.0 kN/m².
Quick facts
- Area
- 15.0 m²
- Beams
- 2 × 45×220
- Posts
- 6 × 95×95
- Rafters
- 45×120 c/c 600
- Footings
- 6
- Boards
- 34
- Total timber
- 146 m
Member sizes
| Member | Size | Utilisation | Governing |
|---|---|---|---|
| Raftersspan 2.44 m · c/c ≤ 600 mm · snow 1.6 kN/m² · g 0.14 kN/m, q 0.96 kN/m | 45×120 c/c 600 | 84% | deflection |
| Beams3 rows · span 2.88 m between posts · g 0.58 kN/m, q 3.90 kN/m | 2 × 45×220 | 79% | bending |
| Postslength 2.64 m · N 7.9 kN (G+Q) · braced, Lef = L | 95×95 | 37% | buckling |
| Battensspan 0.58 m between rafters · g 0.12 kN/m, s 0.96 kN/m | 28×70 c/c 600 | 56% | deflection |
Rafters by snow zone
| Ground snow load sₖ (kN/m²) | Size |
|---|---|
| 1.0Malmö, Helsingborg | 45×220 c/c 900 |
| 1.5Göteborg, Kalmar | 45×220 c/c 600 |
| 2.0Stockholm | 45×120 c/c 600 |
| 2.5Karlstad, Gävle | 45×120 c/c 600 |
| 3.0Sundsvall, Umeå | 45×95 c/c 600 |
| 3.5Luleå | 45×145 c/c 600 |
| 4.5mountain areas | 45×170 c/c 600 |
| 5.5high mountains | 45×120 c/c 600 |
Timber list
| Qty | Size | Length | Treatment |
|---|---|---|---|
| 11 | 28×70 | 3.9 m | C24 untreated |
| 1 | 45×95 | 5.4 m | Pressure treated NTR/AB |
| 2 | 45×95 | 5.1 m | Pressure treated NTR/AB |
| 1 | 45×95 | 1.8 m | Pressure treated NTR/AB |
| 8 | 45×120 | 5.4 m | Pressure treated NTR/AB |
| 1 | 45×120 | 3.0 m | Pressure treated NTR/AB |
| 6 | 45×220 | 3.9 m | Pressure treated NTR/AB |
| 2 | 95×95 | 4.8 m | Pressure treated NTR/AB |
| 2 | 95×95 | 3.0 m | Pressure treated NTR/AB |
Good to know
- Covered roofs catch the wind: anchor every post against uplift (cast-in anchors or bolted post bases). Wind uplift is not checked.
FAQ
How big do the beams need to be?
The beams are 2 × 45×220. Always join beams over a post.
What rafters do I need for a 3×5 m carport with metal roof?
45×120 at 600 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×145 at 600 c/c.
How much timber does it take?
The frame takes 34 boards in standard lengths, 146 m of timber in total. The cut list is optimised to keep offcuts small.
How many footings do I need?
6 footings. The most heavily loaded one carries 7.9 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.
Similar plans
The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.