Svenska Designer →

3×2 m gable roof shed – plans, timber list and sizes

This 3×2 m shed (6.0 m²) with a gable roof is framed with wall studs 45×70 at 600 c/c and rafters 45×95 at 1200 c/c on a timber floor with 4 footings. The roof is sized for snow zone 2.0 kN/m² – see the table below for other parts of Sweden.

Frame drawing: 3×2 m gable roof shed
Frame drawing · 3×2 m gable roof shed · Download drawing (PNG)

Quick facts

Area
6.0 m²
Floor joists
45×120 c/c 591
Floor beams
3 × 45×145
Wall studs
45×70 c/c 600
Rafters
45×95 c/c 1200
Footings
4
Boards
32
Total timber
137 m

Member sizes

MemberSizeUtilisationGoverning
Floor joistsspan 1.87 m · c/c 591 mm · g 0.11 kN/m, q 1.48 kN/m 45×120 c/c 591 80% deflection
Floor beams2 rows · span 2.61 m between posts · g 0.27 kN/m, q 2.44 kN/m 3 × 45×145 72% deflection
Raftershorizontal span 1.00 m · c/c 1,200 mm · snow 1.6 kN/m² · g 0.41 kN/m, s 1.92 kN/m per horizontal metre 45×95 c/c 1200 43% bending
Wall studstallest stud 2.50 m · roof on wall g 0.47 kN/m, s 1.28 kN/m · wind qₚ 0.6 kN/m² 45×70 c/c 600 72% buckling
Header – door 0.9 m×1.9 m, the front wallspan 0.99 m · roof load g 0.47 kN/m, s 1.28 kN/m 45×95 35% bending
Header – window 0.7 m×0.6 m, the left wallspan 0.79 m · non-bearing wall (nominal load) 45×95 6% shear

Rafters by snow zone

Ground snow load sₖ (kN/m²)Size
1.0Malmö, Helsingborg 45×95 c/c 1200
1.5Göteborg, Kalmar 45×95 c/c 1200
2.0Stockholm 45×95 c/c 1200
2.5Karlstad, Gävle 45×95 c/c 1200
3.0Sundsvall, Umeå 45×95 c/c 1200
3.5Luleå 45×95 c/c 1200
4.5mountain areas 45×95 c/c 1200
5.5high mountains 45×120 c/c 1200

Timber list

QtySizeLengthTreatment
1 45×70 5.1 m Pressure treated NTR/AB
1 45×70 4.2 m Pressure treated NTR/AB
5 45×70 5.4 m C24 untreated
1 45×70 4.8 m C24 untreated
8 45×70 4.2 m C24 untreated
1 45×70 3.9 m C24 untreated
1 45×95 5.4 m C24 untreated
1 45×95 5.1 m C24 untreated
1 45×95 3.0 m C24 untreated
2 45×120 5.1 m Pressure treated NTR/AB
2 45×120 3.9 m Pressure treated NTR/AB
1 45×120 5.1 m C24 untreated
1 45×120 2.1 m C24 untreated
6 45×145 3.3 m Pressure treated NTR/AB

FAQ

What size joists do I need for a 3×2 m gable roof shed?

45×120 at 591 mm c/c is enough for 2.5 kN/m² imposed load. That uses 80% of the capacity under Eurocode 5.

How big do the beams need to be?

The beams are 3 × 45×145. Always join beams over a post.

What rafters do I need for a 3×2 m gable roof shed?

45×95 at 1200 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×95 at 1200 c/c.

How much timber does it take?

The frame takes 32 boards in standard lengths, 137 m of timber in total. The cut list is optimised to keep offcuts small.

How many footings do I need?

4 footings. The most heavily loaded one carries 4.1 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.