2.4×1.8 m gable roof shed – plans, timber list and sizes
This 2.4×1.8 m shed (4.3 m²) with a gable roof is framed with wall studs 45×70 at 600 c/c and rafters 45×95 at 1200 c/c on a timber floor with 4 footings. The roof is sized for snow zone 2.0 kN/m² – see the table below for other parts of Sweden.
Quick facts
- Area
- 4.3 m²
- Floor joists
- 45×120 c/c 589
- Floor beams
- 45×145
- Wall studs
- 45×70 c/c 600
- Rafters
- 45×95 c/c 1200
- Footings
- 4
- Boards
- 24
- Total timber
- 107 m
Member sizes
| Member | Size | Utilisation | Governing |
|---|---|---|---|
| Floor joistsspan 1.76 m · c/c 589 mm · g 0.11 kN/m, q 1.47 kN/m | 45×120 c/c 589 | 66% | deflection |
| Floor beams2 rows · span 2.01 m between posts · g 0.20 kN/m, q 2.31 kN/m | 45×145 | 98% | bending |
| Raftershorizontal span 0.90 m · c/c 1,200 mm · snow 1.6 kN/m² · g 0.41 kN/m, s 1.92 kN/m per horizontal metre | 45×95 c/c 1200 | 37% | shear |
| Wall studstallest stud 2.46 m · roof on wall g 0.45 kN/m, s 1.20 kN/m · wind qₚ 0.6 kN/m² | 45×70 c/c 600 | 69% | buckling |
| Header – door 0.9 m×1.9 m, the front wallspan 0.99 m · roof load g 0.45 kN/m, s 1.20 kN/m | 45×95 | 33% | bending |
| Header – window 0.7 m×0.6 m, the left wallspan 0.79 m · non-bearing wall (nominal load) | 45×95 | 6% | shear |
Rafters by snow zone
| Ground snow load sₖ (kN/m²) | Size |
|---|---|
| 1.0Malmö, Helsingborg | 45×95 c/c 1200 |
| 1.5Göteborg, Kalmar | 45×95 c/c 1200 |
| 2.0Stockholm | 45×95 c/c 1200 |
| 2.5Karlstad, Gävle | 45×95 c/c 1200 |
| 3.0Sundsvall, Umeå | 45×95 c/c 1200 |
| 3.5Luleå | 45×95 c/c 1200 |
| 4.5mountain areas | 45×95 c/c 1200 |
| 5.5high mountains | 45×95 c/c 1200 |
Timber list
| Qty | Size | Length | Treatment |
|---|---|---|---|
| 1 | 45×70 | 5.1 m | Pressure treated NTR/AB |
| 1 | 45×70 | 2.7 m | Pressure treated NTR/AB |
| 3 | 45×70 | 5.4 m | C24 untreated |
| 1 | 45×70 | 5.1 m | C24 untreated |
| 1 | 45×70 | 4.5 m | C24 untreated |
| 8 | 45×70 | 4.2 m | C24 untreated |
| 1 | 45×70 | 3.9 m | C24 untreated |
| 1 | 45×70 | 1.8 m | C24 untreated |
| 1 | 45×95 | 5.4 m | C24 untreated |
| 1 | 45×95 | 4.5 m | C24 untreated |
| 1 | 45×120 | 5.4 m | Pressure treated NTR/AB |
| 1 | 45×120 | 5.1 m | Pressure treated NTR/AB |
| 1 | 45×120 | 3.6 m | Pressure treated NTR/AB |
| 1 | 45×120 | 4.5 m | C24 untreated |
| 1 | 45×145 | 5.1 m | Pressure treated NTR/AB |
FAQ
What size joists do I need for a 2.4×1.8 m gable roof shed?
45×120 at 589 mm c/c is enough for 2.5 kN/m² imposed load. That uses 66% of the capacity under Eurocode 5.
How big do the beams need to be?
The beams are 45×145. Always join beams over a post.
What rafters do I need for a 2.4×1.8 m gable roof shed?
45×95 at 1200 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×95 at 1200 c/c.
How much timber does it take?
The frame takes 24 boards in standard lengths, 107 m of timber in total. The cut list is optimised to keep offcuts small.
How many footings do I need?
4 footings. The most heavily loaded one carries 3.0 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.
Similar plans
The calculations are a design aid based on a simplified Eurocode 5. Connections, foundations and stability must be checked on site – have a structural engineer review the design if a permit is required.