This 4×3 m shed (12.0 m²) with a gable roof is framed with wall studs 45×70 at 600 c/c and rafters 45×95 at 1200 c/c on a timber floor with 9 footings. The roof is sized for snow zone 2.0 kN/m² – see the table below for other parts of Sweden.
Quick facts
- Area
- 12.0 m²
- Floor joists
- 45×120 c/c 565
- Floor beams
- 2 × 45×145
- Wall studs
- 45×70 c/c 600
- Rafters
- 45×95 c/c 1200
- Footings
- 9
- Boards
- 48
- Total timber
- 198 m
Member sizes
| Member | Size | Utilisation | Governing |
|---|---|---|---|
| Floor joistsspan 1.46 m · c/c 565 mm · g 0.11 kN/m, q 1.41 kN/m | 45×120 c/c 565 | 40% | bending |
| Floor beams3 rows · span 1.80 m between posts · g 0.33 kN/m, q 3.64 kN/m | 2 × 45×145 | 62% | bending |
| Raftershorizontal span 1.50 m · c/c 1,200 mm · snow 1.6 kN/m² · g 0.41 kN/m, s 1.92 kN/m per horizontal metre | 45×95 c/c 1200 | 97% | bending |
| Wall studstallest stud 2.71 m · roof on wall g 0.56 kN/m, s 1.68 kN/m · wind qₚ 0.6 kN/m² | 45×70 c/c 600 | 84% | buckling |
| Header – door 0.9 m×1.9 m, the front wallspan 0.99 m · roof load g 0.56 kN/m, s 1.68 kN/m | 45×95 | 44% | bending |
| Header – window 0.7 m×0.6 m, the left wallspan 0.79 m · non-bearing wall (nominal load) | 45×95 | 6% | shear |
Rafters by snow zone
| Ground snow load sₖ (kN/m²) | Size |
|---|---|
| 1.0Malmö, Helsingborg | 45×95 c/c 1200 |
| 1.5Göteborg, Kalmar | 45×95 c/c 1200 |
| 2.0Stockholm | 45×95 c/c 1200 |
| 2.5Karlstad, Gävle | 45×120 c/c 1200 |
| 3.0Sundsvall, Umeå | 45×120 c/c 1200 |
| 3.5Luleå | 45×145 c/c 1200 |
| 4.5mountain areas | 45×145 c/c 1200 |
| 5.5high mountains | 45×170 c/c 1200 |
Timber list
| Qty | Size | Length | Treatment |
|---|---|---|---|
| 2 | 45×70 | 4.5 m | Pressure treated NTR/AB |
| 1 | 45×70 | 4.2 m | Pressure treated NTR/AB |
| 6 | 45×70 | 5.4 m | C24 untreated |
| 1 | 45×70 | 4.8 m | C24 untreated |
| 13 | 45×70 | 4.2 m | C24 untreated |
| 1 | 45×95 | 5.1 m | C24 untreated |
| 1 | 45×95 | 4.8 m | C24 untreated |
| 3 | 45×95 | 3.9 m | C24 untreated |
| 2 | 45×120 | 4.2 m | Pressure treated NTR/AB |
| 8 | 45×120 | 3.0 m | Pressure treated NTR/AB |
| 1 | 45×120 | 4.2 m | C24 untreated |
| 3 | 45×120 | 3.3 m | C24 untreated |
| 6 | 45×145 | 4.2 m | Pressure treated NTR/AB |
FAQ
What size joists do I need for a 4×3 m gable roof shed?
45×120 at 565 mm c/c is enough for 2.5 kN/m² imposed load. That uses 40% of the capacity under Eurocode 5.
How big do the beams need to be?
The beams are 2 × 45×145. Always join beams over a post.
What rafters do I need for a 4×3 m gable roof shed?
45×95 at 1200 mm c/c in snow zone 2.0. In snow zone 3.5 you need 45×145 at 1200 c/c.
How much timber does it take?
The frame takes 48 boards in standard lengths, 198 m of timber in total. The cut list is optimised to keep offcuts small.
How many footings do I need?
9 footings. The most heavily loaded one carries 7.2 kN, which on firm friction soil means a footing of roughly Ø300–400 mm.
Similar plans